MECHANICAL CHARACTERISTICS
Designation | Admissible longitudinal stress daN | Separation between adjacent phases or to the “a” mast axis (mm) |
---|---|---|
CBTA-HV1-1750 | 125 | 1750 |
CBTA-HV1-2000 | 125 | 2000 |
CBTA-HV2-1750 | 225 | 1750 |
CBTA-HV2-2000 | 225 | 2000 |
Designation | Load cases | Workloads + overload daN V | Workloads + overload daN L | Workloads + overload daN F | Safety factor | Specified limit load Test loads daN V V | Specified limit load Test loads daN L | Specified limit load Test loads daN F | Specified limit load Test loads Duration seconds |
---|---|---|---|---|---|---|---|---|---|
CBTA-HV1 | A | 300 | – | 300 | 1.5 | 450 | – | 450 | 60 |
CBTA-HV1 | B | 300 | 125 | – | 1.5 | 450 | 188 | – | 60 |
CBTA-HV2 | A | 300 | – | 300 | 1.5 | 450 | – | 450 | 60 |
CBTA-HV2 | B | 300 | 225 | – | 1.5 | 450 | 338 | – | 60 |